For more details call or WhatsApp on +91 96575 55530

Dermateec Micro Needling RF

Price on request
Message us for pricing and availability.

MiFocus RF combines fine insulated microneedles with precisely controlled radiofrequency (RF) energy to stimulate collagen remodeling at multiple depths of the skin. Nutritional serums are delivered through the microneedle channels

MiFocus RF

Targeted Rejuvenation, Deep Healing Redefined

while RF thermal energy is released exactly at the needle tips, giving practitioners a safe, minimally invasive way to treat sagging, wrinkles, enlarged pores, stretch marks, acne scars, and more — with virtually no downtime for the client.

Product Overview

RF Microneedling treatment is built on the combination of fine microneedle tips and radiofrequency (RF) energy. Nutritional serums are applied to the skin surface and carried into deeper skin layers through the microneedle channels.

Once the microneedles penetrate into the dermis, RF energy is released precisely from the needle tips the moment they reach the targeted depth, delivering thermal energy directly into the dermis for optimal collagen stimulation.

The device is equipped with two technologies — microneedling RF and standard (fractional) RF. Microneedling RF treatment tips are available in five configurations (9, 14, 25, 36, 49 pins), allowing customized treatment across different facial and body areas. With adjustable penetration depth and energy settings, MiFocus RF enables tailored treatments for various skin types and concerns, offering a safe, minimally invasive solution with visible, long-lasting results.

Insulated Delivery

RF energy travels through insulated microneedles that reach depths of 0.5–3.5mm, activating dermal remodeling at multiple skin layers.

Tip-Concentrated Energy

RF energy is concentrated at the needle tips, minimizing surface damage while allowing precise repair of target areas through adjustable needle depth and energy settings.

How It Works — Step by Step

  1. Cleanse & Prep

    The treatment area is cleansed and a topical numbing cream is applied for client comfort, then a nutritional serum is applied to the skin surface.

  2. Select Tip & Mode

    The practitioner selects a microneedle tip configuration (9 / 14 / 25 / 36 / 49 pins) and one of the three operating modes — MicroRF, FocusRF-S, or FocusRF-M — based on the treatment goal and body area.

  3. Set Depth & Energy

    Needle penetration depth (0.4–3.5mm) and RF power are dialed in on the touchscreen to match the target treatment layer, from the epidermal basement membrane down to the fat layer.

  4. Microneedle Penetration

    Ultra-fine 0.12mm insulated needles penetrate the skin. Because the needles are insulated, RF energy cannot leak into the epidermis on the way in.

  5. Targeted RF Release

    The instant each needle reaches its programmed depth, RF energy is released precisely from the tip, heating the dermis directly and triggering collagen and elastin remodeling — while the surface layer stays virtually undamaged.

  6. Serum Infusion

    The microneedle channels also allow nutritional serums to be carried into deeper skin layers for enhanced absorption during the same session.

  7. Recovery

    Clients typically experience only mild redness for 6–12 hours. Makeup and normal social activity can resume the same day.

Key Advantages

Insulated Needles

Energy is confined to the needle tips, protecting the epidermis from unwanted heat exposure.

Insulated needle RF energy diagram

Multi-level RF Delivery (0.5–3.5mm adjustable)

Using a layered radiofrequency energy delivery technology (0.5–3.5mm adjustable), MiFocus RF precisely heats different skin depths, stimulating collagen and elastic fibers at various levels. This effectively enhances skin tightening and improves overall skin texture.

Treatment Layer Depth Range Target Tissue Indications
L1 0.5–0.8 mm Epidermal Basement Membrane Pigmentation / Superficial Fine Lines
L2 1.0–1.5 mm Papillary Dermis Enlarged Pores / Mild Acne
L3 1.8–2.2 mm Reticular Dermis Nasolabial Folds / Neck Lines / Stretch Marks
L4 2.5–3.0 mm Superficial Musculoaponeurotic System (SMAS) Facial Lifting / Contour Reshaping
L5 3.0–3.5 mm Fat Layer Axillary Odor / Stubborn Scars

Ultra-Fine 0.12mm Needles for Minimal Discomfort

Ultra-fine 0.12mm microneedles reduce discomfort during treatment, ensuring a more comfortable client experience.

Multi-Needle Matrix

9 / 14 / 25 / 36 / 49 pins for customized applications — five interchangeable tip configurations let practitioners match needle density to the treatment area and concern.

MiFocus RF multi-needle tip configurations 9/14/25/36/49 pins

Tip configurations: 2×7, 3×3, 5×5, 6×6, 7×7 (9 / 14 / 25 / 36 / 49 pins)

  • Medical-Grade: sterile tips for enhanced safety
  • Minimal Downtime: no impact on daily life
  • Microneedling RF combined with focused RF delivers precise thermal stimulation and deeper collagen remodeling for enhanced tightening and skin texture improvement.

Technical Highlights

Non-invasive Repair

Nearly zero damage to the epidermis, with no scabbing or pigmentation risk (traditional fractional laser has a 15% pigmentation rate vs. <0.3% with gold RF microneedling).

Precise Multi-layered Treatment

Targets different tissue depths to address a variety of skin concerns effectively.

Fast Recovery

Only mild redness for 6–12 hours post-treatment; makeup and social activities can resume the same day (vs. 3–7 days recovery for traditional microneedling).

One-Stop Skin Renewal

Offers a one-stop solution for various skin concerns, including sagging, wrinkles, enlarged pores, stretch marks, and acne scars — leaving the skin firmer, smoother, and more youthful.

Skin cross-section before and after RF microneedling treatment

Skin cross-section before and after RF microneedling treatment

Interface & Operating Modes

MiFocus RF offers 3 operating modes for customized treatments, including 3 professional protocols, all managed from an intuitive touchscreen interface.

Micro RF

Delivers fractional RF energy via insulated microneedles with adjustable depth and power. Precisely targets the dermis to stimulate collagen regeneration and improve acne scars, pores, wrinkles, and skin laxity — ideal for minimally invasive, high-precision treatments.

Focus RF-S

A superficial radiofrequency mode designed for delicate or smaller areas. Provides controlled heating at 35–45°C to tighten skin, refine texture, and reduce fine lines with a gentle, non-invasive approach.

Focus RF-M

A medium-depth RF treatment mode that delivers focused energy to deeper skin layers. Suitable for larger or more stubborn areas needing firming, contouring, and collagen remodeling. Temperature and power are adjustable for customized care.

Application Areas

  • Acne scars
  • Post-inflammatory hyperpigmentation
  • Regular anti-aging maintenance
  • Facial laxity
  • Fine lines
  • Active acne
  • Stretch marks
  • Skin laxity
  • Enlarged pores & dull texture
  • Eye bags & dark circles
  • Hyperhidrosis & body odor
  • Burn or trauma scars

Business Value

  • Offer differentiated treatments with advanced microneedle RF technology
  • Quick results and minimal downtime attract repeat clientele
  • Suitable for broad indications across face and body
  • Enhances your service portfolio with premium, result-driven procedures
  • Ideal for clinics, spas, distributors, and global resellers

Specifications

Input

Input voltage range110–240 VAC
Frequency range50/60 Hz
Max current — Standby / RF / Microneedling0.27A / 0.64A / 0.34A
Max power — Standby / RF / Microneedling63VA / 148VA / 79VA

RF Output

Power1–50 W, adjustable in 1W increments
Treatment time1–60 min, adjustable in 1-minute increments
Temperature protection35–45°C

Microneedling Output

Power1–12 W, adjustable in 1W increments
Needle configurations9 / 14 / 25 / 36 / 49 pin, depth adjustable 0.4–3.5mm
Pulse width1–100 ms
Vacuum pressure≤ 70 KPa
Total shots (tip life)1,200 shots

Dimensions & Weight

Machine dimensions517 × 423 × 1334 mm
Packaging dimensions660 × 670 × 1515 mm
Gross weight79.5 kg
Net weight34.6 kg

About ADSS: 20 years shaping a leading brand in medical aesthetic device manufacturing, 200+ independently developed patented technologies, 500+ optoelectronic devices covering the entire medical aesthetic product line, serving clients in 200+ countries and regions.

Want pricing, a demonstration or more detail on this machine?

Interested in the Dermateec Micro Needling RF?

Send us your configuration on WhatsApp and we will come back with pricing, availability and a demonstration slot.

Request a callback