🔬 The Science Behind It
It emits at 10,600nm, a far-infrared wavelength with high absorption in water. This lets the laser incise, evaporate, and coagulate tissue with precision while avoiding significant absorption by melanin or oxyhemoglobin — meaning treatment accuracy stays high with minimal scattering or reflection loss, even on pigmented or vascular skin.
- High Accuracy: Low reflection and scattering allow the beam to strike its target with tight precision.
- Safety: Water-selective absorption limits collateral thermal spread to surrounding tissue.
- Effective: Controlled micro-injury triggers the skin's natural collagen remodeling response — visible in the before/during/after tissue cross-section.
✨ Clinical Functions
Improve skin quality and stimulate rejuvenation across six core applications:
🦾 Imported Articulated Arm (South Korea)
- Special Seven-Joint Design: A dedicated seven-joint articulated arm gives the operator full range of motion around the treatment area.
- High-Frequency RF Tube: Long service life paired with higher output quality and consistency.
- 9 Optical Lenses, 99%+ Reflectivity: Smaller energy loss along the beam path translates to higher clinical efficiency.
- Center Red Light Deviation <0.5mm: Delivers highly accurate targeting, especially valuable for small-area lesions.
- Adjustable Aiming Beam (1–5mW): Continuously tunable for clearer visualization during clinical work, while protecting the operator and making the lesion area easy to observe.
⚙️ True Ultra-Pulsed Power Delivery
The terminal laser power is continuously adjustable across a low-power range of 1–40W, meeting precise treatment needs while helping avoid clinical complications.
- True 40W Output to Tissue: Low transmission loss preserves clinical effect at full power.
- Stable Low-End Output: True energy delivery starting from 1W solves the common problem of energy instability at low settings.
- Clean Vaporization Points: During treatment, the true ultra-pulsed CO2 beam produces only controlled white vaporization points — deep penetration with thermal stimulation and thermal damage that stay controllable and limited, unlike less-refined competitor beams.
🏥 Clinical Application & Interface
- Patented Surface Grinding Technology: More effective for treating acne pits and scars.
- Superficial/Deep Alternating Treatment: A unique dual-depth technology mode for versatile tissue response.
- 6 Treatment Modes, 8 Handpieces: Covers the clinical needs of multiple departments from one console.
- Medical Certification-Level Interface: Non-adjustable parameter presets for defined clinical treatments reduce accidents, shorten recovery periods, and improve precision and outcomes.
Touchscreen application presets include: Surface, Deep, Full Layer, Expert, Pigment, Onychomycosis, Skinning, and Privacy modes, each paired with a matched handpiece (F50S, F50SH, F100S, F100SH, F50V, F200, F20DR, F50S, F100V, F50, F100, PHY).
🧩 Accessories
- Facial Treatment Tips: F50S, F50SH, F100S, F100SH — sized for pigment, acne, texture, and onychomycosis (nail fungus) applications.
- Surgical Handpieces: Dedicated handheld units for surgical CO2 laser procedures.
🔲 Spot Pattern Technology
8 spot modes — square, circle, hexagon, rectangle, ellipse, triangle, line, and hollow circle — cover the treatment needs of all body and facial areas.
- Spiral Micro-Beam Scanning: Expands treatment area coverage for efficient skin resurfacing.
- Spiral Thermal Protection Zone: The hollow spiral gap pattern promotes faster skin repair compared to standard fixed-dot grids used by other systems.
🩺 SUI / VR Handles
The newest-generation RF tube supports an exchangeable handpiece for both CO2 fractional laser and ultra-pulsed CO2 laser procedures. This makes it an advanced option for gynecological treatment — stimulating collagen within the vaginal mucous membrane to improve elasticity, address symptoms of stress urinary incontinence, and relieve conditions such as vaginal dryness or vaginitis, using the dedicated:
- SUI Handpiece (Stress Urinary Incontinence)
- VR Handpiece (Vaginal Rejuvenation)
Disposable Sterile Tube
A single-use disposable private sleeve prevents cross-infection between patients — safe, convenient, and suited to both beauty salons and clinical settings.
- Vaginal tightening and elasticity increase
- Collagen remodeling of vaginal tissue
- Treatment of insufficient vaginal secretion
- Vaginal anti-inflammatory support, developing immunity
- Remission of vaginal dryness and urinary incontinence
Vaginal and urinary-health applications should be performed by a trained clinician in accordance with local medical device regulations.
📋 Technical Specifications
| Laser Type | UltraPulse and CW |
|---|---|
| Wavelength | 10,600 nm |
| Power to Tissue | 40 W |
| Display | 10.4-inch touch screen |
| Power of Aiming Beam | ≤5 mW |
| Laser Operating Mode | Ultra pulse, fractional |
| Scanning Mode | Free scan, sequence scan, interline scan |
| Scan Area | 1×1 – 20×20 mm |
| Beam Mode | TEM00 < 1.1 M² |
| Beam Divergence Angle | 0.3 mrad |
| Spot Size | 0.12 / 2.0 mm |
| Spot Pattern | Circle / Ellipse / Triangle / Square / Rectangle / Hexagon / Line / Hollow Circle |
| Beam Delivery | 7-joint articulated arm |
| Aiming Beam | 5 mW, 635nm infrared, adjustable intensity |
| Cooling System | Air |
| Electrical | 100–240VAC, 50/60Hz |
| Accessories | Vaginal probes (360° full-angle), VR HP, SUI HP, CO₂ HP (f=50mm / f=100mm) |
| Dimension | 57 × 90 × 136 cm |
| Weight | 80 kg |
💼 Why it Fits our Treatment Menu
By combining an internationally certified (ISO13485, CE, FDA, TÜV) resurfacing platform with an interchangeable gynecological applicator, it lets a practice serve dermatology and women's-health treatment demand from one console — reducing floor space, capital outlay, and consumable SKUs versus running separate single-purpose systems.