🔬 Theory
This emits at 10,600nm, a far-infrared wavelength with high absorption in water. This lets the laser incise, evaporate, and coagulate tissue with precision, while low reflection and scattering allow the beam to shoot with high accuracy — supporting the device's core aims of accuracy, safety, and effectiveness at every treatment stage, from before, during, to after tissue response.
✨ Function
Improve skin quality and rejuvenation across six core applications:
🦾 Torsion Spring Light Guide Arm
- Torsion Spring Design: A smooth, low-resistance light guide arm gives the operator full control and reach around the treatment area.
- High-Frequency RF Tube: Long service life paired with higher output quality.
- 9 Optical Lenses, 99%+ Reflectivity: Smaller energy loss along the beam path for higher clinical efficiency and longer service life.
- Center Red Light Deviation <0.4mm: Delivers accurate targeting, especially suited to small-area lesions.
- Adjustable Aiming Beam (1–5mW): Continuously tunable for clearer visualization during clinical work, making the lesion area easy to observe while protecting the operator.
⚙️ True Ultra-Pulsed Power Delivery
The terminal laser power is continuously adjustable across a low-power range of 1–30W, meeting the doctor's precise treatment needs while helping avoid clinical complications.
- True 30W Output to Tissue: Low transmission loss preserves clinical effect at full power.
- Stable Low-End Output: True energy delivery starting from 1W solves the common problem of energy instability at low settings.
- Clean Vaporization Points: During treatment, only controlled white vaporization points are produced — the energy penetrates deeply while thermal stimulation and thermal damage stay controllable and limited.
🏥 Clinical Application
- Patented Surface Grinding Technology: More effective for treating acne pits and scars.
- Superficial/Deep Alternating Treatment: A unique dual-depth technology mode for versatile tissue response.
- 6 Treatment Modes, 8 Handpieces: Covers the clinical needs of multiple departments from one console.
- Medical Certification-Level Interface: Non-adjustable parameter presets for defined clinical treatments reduce accidents, shorten recovery periods, and improve precision and outcomes.
🧩 Accessory Advantages
This abandons the traditional galvanoscope dismounting link, eliminating the hidden risk of dust entry at its root. This keeps the operator working in a clean, stable environment, extends the device's service life, and saves clinical operators time and energy.
- F50S Tip: For facial treatment, including onychomycosis (nail fungus) applications.
- F100 Handpiece: For surgery treatment.
🔲 Spot Pattern Technology
8 spot modes — square, circle, hexagon, rectangle, triangle, line, and hollow circle — cover the treatment needs of all areas.
Precision focusing accurately targets the treatment area and causes less damage to surrounding normal skin tissue than traditional laser treatment, resulting in:
🩺 SUI / VR Handles
This is the newest-generation RF tube supports an exchangeable handpiece for both CO2 fractional laser and ultra-pulsed CO2 laser procedures. This makes it an advanced conceptual device for gynecological treatment — stimulating collagen within the vaginal mucous membrane to make the vaginal canal more elastic after the procedure, improving symptoms of urinary incontinence and other lesions such as vaginitis and vaginal dryness, using the dedicated:
- SUI Handpiece (Stress Urinary Incontinence)
- VR Handpiece (Vaginal Rejuvenation)
Vaginal Treatment
- Vaginal tightening and elasticity increase
- Collagen remodeling of vaginal tissue
- Treatment of insufficient vaginal secretion
- Vaginal anti-inflammatory support, developing immunity
- Remission of vaginal dryness and urinary incontinence
Vaginal and urinary-health applications should be performed by a trained clinician in accordance with local medical device regulations.
📋 Technical Specifications
| Laser Type | UltraPulse and CW |
|---|---|
| Wavelength | 10,600 nm |
| Power to Tissue | 30 W |
| Display | 10.4-inch touch screen |
| Laser Operating Mode | Ultra pulse, fractional |
| Scanning Mode | Free scan, sequence scan, interline scan |
| Scan Area | 1×1 – 20×20 mm |
| Beam Mode | TEM00 < 1.1 M² |
| Beam Divergence Angle | 0.4 mrad |
| Spot Size | < 0.4 mm |
| Spot Pattern | Circle / Ellipse / Triangle / Square / Hexagon / Line / Hollow Circle |
| Beam Delivery | Torsion spring light guide arm |
| Aiming Beam | 5 mW, 635nm infrared, adjustable intensity |
| Cooling System | Air cooling system |
| Dimension | 58 × 65 × 55 cm |
| Weight | 30 kg |
💼 Why this Fits Your Treatment Menu
Lighter and more compact than a full-size console, this brings the same true ultra-pulsed power delivery and interchangeable gynecological applicator to practices that need a portable, all-in-one resurfacing and women's-health platform without giving up clinical-grade performance.